■SC-GU3-□
■SC-HG1-□
Model No. | SC-GU3-04 |
---|---|
Applicable regulations | CE Marking (EMC Directive (Note 1), RoHS Directive), UKCA Marking (EMC Regulations (Note 1), RoHS Regulations) |
Compatible sensor units | Sensor amplifiers (NPN output type) that can connect to the SC‑71 cascading connector unit (optional) |
Number of units connectable | Maximum of 16 units can be connected to one SC-GU3-04 unit (Max. 12 units when FX500 / LS-500 series is connected) |
Supply voltage | 24 V DC +10-15 % Ripple P-P 10 % or less |
Current consumption | 200 mA or less (excluding connected sensor amplifiers) |
Allowable passing current | 2A or less (Note 2) |
Communication method | CC-Link IE Field |
Remote station type | Remote device station |
Transmission line types | Line, star (mixing of line and star types is possible), ring |
Network No. setting | 1 to 239 (decimal) [1 to EF (hex)] (0 and 240 or higher result in an error) (Note 3) |
Station No. setting | 1 to 120 (decimal) (0 and 121 or higher result in an error) |
Communication speed | 1 Gbps |
Maximum overall cable distance | 100 m 328.084 ft |
Ambient temperature | -10 to +50 ℃ +14 to +122 ℉ (8 to 16 units connected: -10 to +45 ℃ +14 to +113 ℉) (No dew condensation or icing allowed) Storage: -20 to +70 ℃ -4 to +158 ℉ |
Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH |
Material | Enclosure: Polycarbonate |
Net weight | 100 g approx. |
Notes:
1) | Ground the shield wire of the Ethernet cable at a higher-level device in order to comply with the EMC Directives / EMC Regulations. This product is not provided with a grounding terminal. For details, refer to the CC-Link IE Field Network Cable Installation Manual published by the CC-Link Partner Association. |
---|---|
2) | Take care that the total consumption current of connected sensor amplifiers and other devices does not exceed the allowable passing current. |
3) | For the Network No. setting of this product, set a value converted to hexadecimal. |
Item | SC-GU3-01 | ||||
---|---|---|---|---|---|
Applicable regulations | CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations) | ||||
Number of connectable units | Maximum of 16 units per SC-GU3-01 unit (Max. 12 units when FX-500 / LS-500 series are connected) | ||||
Supply voltage | 24 V DC +10-15% Ripple P-P 10 % or less | ||||
Current consumption | 120 mA or less (without connected sensor amplifiers) | ||||
Allowable passing current | Wire-saving connector 2 A (Note 1), supply connector 6 A (Note 2) | ||||
Communication method | CC-Link Ver.1.10 | ||||
Number of occupied station | Switchable 1 or 4 station | ||||
Baud rate | 10 Mbps | 5 Mbps | 2.5 Mbps | 625 kbps | 156 kbps |
Total extension length | 100 m 328.084 ft | 150 m 492.126 ft | 200 m 656.168 ft | 600 m 1968.504 ft | 1,200 m 3937.008 ft |
Communication cable | Specified cable (twist pair cable with shield) (Note 3) | ||||
Station No. setting | 1 to 64 (0 and 65 or more: Error) | ||||
Remote station type | Remote device station | ||||
Ambient temperature | –10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), (If 4 to 7 units are connected in cascade: –10 to +50 ℃ +14 to +122 ℉, if 8 to 16 units are connected in cascade: –10 to +45 ℃ +14 to +113 ℉) Storage: –20 to +70 ℃ –4 to +158 ℉ |
||||
Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH | ||||
Material | Enclosure: Polycarbonate | ||||
Weight | Net weight: 80 g approx., Gross weight: 120 g approx. |
Notes:
1) | Be sure to check that total current consumption of sensor amplifiers connected in cascade does not exceed allowable passing current. |
---|---|
2) | In case of supplying power to other devices, be sure to set the current less than allowable passing current. |
3) | Use only a special-use communication cable that is approved by the CC-Link Partner Association. |
Item | SC-GU3-EU |
---|---|
CE marking directive compliance | EMC Directive, RoHS Directive |
Number of connectable units | 1 unit for 1 communication unit |
Supply voltage | 11 to 25 V DC Ripple P-P 10 % or less |
Current consumption | 25 mA or less |
Power indicator | Green LED (lights up when the power is ON) |
Ambient temperature | –10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), (If 4 to 7 units are connected in cascade: –10 to +50 ℃ +14 to +122 ℉, if 8 to 16 units are connected in cascade: –10 to +45 ℃ +14 to +113 ℉) Storage: –20 to +70 ℃ –4 to +158 ℉ |
Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH |
Material | Enclosure: Polycarbonate |
Weight | Net weight: 20 g approx., Gross weight: 20 g approx. |
Item | SC-71 |
---|---|
Number of connectable units | Max. 16 units per 1 communication unit |
Ambient temperature | –10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), (If 4 to 7 units are connected in cascade: –10 to +50 ℃ +14 to +122 ℉, if 8 to 16 units are connected in cascade: –10 to +45 ℃ +14 to +113 ℉) Storage: –20 to +70 ℃ –4 to +158 ℉ |
Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH |
Material | Enclosure: Polycarbonate, Metal plate: Aluminum |
Weight | Net weight: 10 g approx., Gross weight: 25 g approx. |
Item | SC-E1 |
---|---|
Supply voltage | 12 to 24V DC ±10% |
Current consumption | 20 mA or less (with all indicators on) (Note 1) |
Number of signals | 1 input |
Input | Connectable devices: NPN open-collector transistor output type (Input 1) sensor, DC 2-wire output type (Input 2) sensor (Note 2), switches, and other devices Current supply for input device: 100 mA or less Input impedance: 17 kΩ approx. (Input 1) or 3.2 kΩ approx. (Input 2) |
Output | NPN open-collector transistor • Maximum sink current: 50 mA • Applied voltage: 30 V DC or less (between output and 0 V) • Residual voltage: 1.5 V or less (with sink current of 50 mA) |
Power indicator | Green LED (Lights up when the power is ON) |
Input indicator | Green LED (Lights up when input is being received by unit) |
Ambient temperature | –10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), (If 4 to 7 units are connected in cascade: –10 to +50 ℃ +14 to +122 ℉, if 8 to 16 units are connected in cascade: –10 to +45 ℃ +14 to +113 ℉) Storage: –20 to +70 ℃ –4 to +158 ℉ |
Ambient humidity | 35 to 85% RH Storage:35 to 85% RH |
Material | Enclosure: Flame-resistant PBT Connector: Polyester |
Weight | Net weight: 15g approx., Gross weight: 40g approx. |
Accessory | Connector (e-CON): 1pc. |
Notes:
1) | Does not include current consumption or input current for connected input devices. |
---|---|
2) | Conditions of connectable DC 2-wire type input device ・Leak current: 1 mA or less (when the power is OFF), Offset voltage: 3 V or less (when the power is ON) ・ Product whose load current range includes 5 to 8 mA |
Item | SC-E81 |
---|---|
Supply voltage | 12 to 24V DC ±10% |
Current consumption | 60 mA or less (with all indicators on) (Note 1) |
Number of signals | 8 inputs (Note 2) |
Input | Connectable devices: NPN transistor / open-collector output type
sensors, switches, and other devices Current supply for input devices: 800 mA or less (total for 8 inputs) Input impedance: Approx. 17 kΩapprox |
Output | NPN open-collector transistor • Maximum sink current: 50 mA • Applied voltage: 30 V DC or less (between output and 0 V) • Residual voltage: 1.5 V or less (with sink current of 50 mA) |
Power indicator | Green LED (lights up when the power is ON) |
Input indicator | 8 green LEDs (light up when input is received from the corresponding channel) |
Ambient temperature | –10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), (If 4 to 7 units are connected in cascade: –10 to +50 ℃ +14 to +122 ℉, if 8 to 9 units are connected in cascade: –10 to +45 ℃ +14 to +113 ℉) Storage: –20 to +70 ℃ –4 to +158 ℉ |
Ambient humidity | 35 to 85% RH Storage: 35 to 85% RH |
Material | Enclosure: Polycarbonate Connector: Polyester |
Weight | Net weight: 40g approx., Gross weight: 85g approx. |
Notes:
1) | Does not include current consumption or input current for connected input devices. |
---|---|
2) | Uses eight channels of signaling, regardless of the number of connected input devices. |
Item | SC-E82 |
---|---|
Supply voltage | 5 to 24 V DC ±10% |
Current consumption | 7mA or less |
Number of signals | 8 inputs (Note 1) |
Input | Connectable devices: NPN open-collector transistor output type sensors, switches, and other devices (Note 2) Current supply for input devices: 800 mA or less (total for 8 inputs) |
Power indicator | Green LED (Lights up when the power is ON) |
Ambient temperature | –10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), (If 4 to 7 units are connected in cascade: –10 to +50 ℃ +14 to +122 ℉, if 8 to 9 units are connected in cascade: –10 to +45 ℃ +14 to +113 ℉) Storage: –20 to +70 ℃ –4 to +158 ℉ |
Ambient humidity | 35 to 85% RH Storage: 35 to 85% RH |
Material | Enclosure: Polycarbonate Connector: Polyester |
Weight | Net weight: 40g approx. Gross weight: 85g approx. |
Notes:
1) | Uses eight channels of signaling, regardless of the number of connected input devices. |
---|---|
2) | When using in combination with the SC-MIL, it can use as a commercially available device including a DC 2-wire type sensor or output. Refer to the SC series for the SC-MIL. |
Item | Analog voltage input unit | Analog current input unit |
---|---|---|
SC-A01 | SC-A02 | |
Supply voltage | 12 to 24V DC±10%, Ripple P-P 10% or less | |
Current consumption | 25 mA or less (with all indicators on and 24 V applied) (Note 1) | |
Analog input | Voltage: 1 to 5 V DC (input impedance: approx. 200 kΩ) | Current: 4 to 20 mA DC (input impedance: approx. 250 kΩ) |
Communication data (Note 2) |
Analogue ⇔ Communication data ・Communication data: 0 to 4,000 digits (within range of 1 to 5 V) ・Zero point: Within 0 digit ±0.5% F.S. (within the range of 1 to 5V) ・Span: Within 4,000 digits ±0.5% F.S. ・Linearity: Within ±0.5% F.S. |
Analogu ⇔ Communication data ・Communication data: 0 to 4,000 digits (within range of 4 to 20 mA) ・Zero point: Within 0 digit ±0.5% F.S. ・Span: Within 4,000 digits ±0.5% F.S. ・Linearity: Within ±0.5% F.S. |
Input | Connectable devices: NPN open-collector transistor output type Current supply for input devices: 100 mA or less Input impedance: 17 kΩ approx. Operating voltage: On voltage of 17 V or more (between input and +V, 24 V applied) Off voltage of 4 V or less (between input and +V, 24 V applied) |
|
Output | NPN open-collector transistor • Maximum sink current: 50 mA or less (when expanding to 5 units or more, 25 mA) • Applied voltage: 30 V DC or less (between output and 0 V) • Residual voltage: 1.5 V or less (with sink current of 50 mA) |
|
Power indicator | Green LED (lights up when the power is ON) | |
Input indicator | Green LED (lights up when input is being received by unit) | |
Ambient temperature | –10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), (If 4 to 7 units are connected in cascade: –10 to +50 ℃ +14 to +122 ℉, if 8 to 16 units are connected in cascade: –10 to +45 ℃ +14 to +113 ℉) Storage: –20 to +70 ℃ –4 to +158 ℉ |
|
Ambient humidity | 35 to 85% RH, Storage: 35 to 85% RH | |
Material | Case: Flame-resistant PBT, Connector: Polyester | |
Weight | Net weight: 15 g approx., Gross weight: 40 g approx. | |
Accessory | Connector (e-CON): 1 |
Note:
1) | Does not include current consumption or input current for connected input devices. |
---|---|
2) | The figure below illustrates the relationship between communication data and input voltage. |
Communication compatibility |
Type | Model No. |
---|---|---|
Models that support optical communications |
Digital fiber sensor (Note) | FX-501, FX-502, FX301, FX-305 |
Digital laser sensor | LS-403, LS-501 | |
Digital pressure sensor | DPS-401, DPS-402 | |
1ch connector input unit (analog communication unit) |
SC-A01, SC-A02 | |
No optical communications | Digital fiber sensor (Note) | FX-551, FX-411, FX-412, FX-301(B/G/H), FX-301-HS |
Manually Set Fiber Sensor | FX-311(B/G) | |
Digital laser sensor | LS-401 | |
Compact inductive proximity sensor | GA-311 | |
1ch connector input unit | SC-E1 | |
8ch connector input unit | SC-E81, SC-E82 |
Note: | FX-301 fiber sensor products manufactured before June 2004 are not compatible with optical communication. Those produced from June 2004 are compatible with optical communication. If "NAVI" is printed only on one side of the product, the unit is not compatible with optical communication. If "NAVI" is printed on both sides of the product, the unit is compatible with optical communication. Please check when using FX-301 fiber sensors. |
---|
|
Model No. | SC-HG1-CEF | |
---|---|---|
Applicable regulations | CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations) | |
Compatible controllers | HG-SC□, HG-TC□ | |
Maximum number of connectable controllers | Maximum of 15 controllers (one master, 14 slaves) per SC‑HG1‑CEF unit | |
Supply voltage(Note 2) | 24V DC ±10%, including 0.5V ripple (P-P) | |
Current consumption | 200 mA or less | |
Communication method | CC-Link IE Field | |
Remote station type | Remote device station | |
Network No. setting | 1 to 239 (decimal) [1 to EF (hex)] (0 and 240 or more: Error)(Note 3) | |
Cyclic transmission (Maximum number of links per station) |
RX/RY:128 points each (128 bits), 16 bytes, RWr/RWw: 64 points each (64 words), 128 bytes |
|
Transient transmission | Server function only, data size 1024 bytes | |
Station No. setting | 1 to 120 (decimal) (0 and 121 or more: Error) | |
Communication speed | 1 Gbps | |
Transmission line type | Line, star, (mixing of line and star types is possible), ring | |
Maximum transmission distance | 100 m 328.084 ft | |
Maximum number of units connectable | 121 units (1 master station, 120 slave stations) | |
Cascade connection levels | Maximum 20 | |
Pollution degree | 2 | |
Operating altitude | 2,000 m 6561.68 ft or less(Note 4) | |
Environmental resistance |
Protection | IP40 (IEC) |
Ambient temperature | -10 to +45 ℃ +14 to +113 ℉ (No dew condensation or icing allowed) Storage: -20 to +60 ℃ -4 to +140 ℉ |
|
Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH | |
Voltage withstandability |
1,000 V AC for one min. between all supply terminals connected together and enclosure |
|
Insulation resistance |
20 MΩ or more, with 250 V DC megger between all supply terminals connected together and enclosure |
|
Vibration resistance | 10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude (10 to 58Hz), maximum acceleration 49 m/s2 (58 to 150 Hz) in X, Y and Z directions for two hours each | |
Shock resistance | 98 m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each |
|
Material | Enclosure: Polycarbonate | |
Communication cable | Ethernet cable that satisfies 1000BASE-T standard Category 5e or higher (Double-shielded / STP, straight cable)(Note 5) |
|
Weight | Net weight: 100 g approx., Gross weight: 150 g approx. |
Notes:
1) | Where measurement conditions have not been specified precisely, the conditions used were ambient temperature +20 ℃ +68 ℉. |
---|---|
2) | Power is supplied from a connected controller / master controller. |
3) | For the network number setting on this product, convert the network number to hex and set the hex value. |
4) | Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m. |
5) | Use CC-Link Partner Association recommended cable. |
Model No. | SC-HG1-C | |||||
---|---|---|---|---|---|---|
Applicable regulations | CE Marking (EMC Directive (Note 2), RoHS Directive), UKCA Marking (EMC Regulations (Note 2), RoHS Regulations) | |||||
Compatible controllers | HG-SC□, HG-TC□ | |||||
Maximum number of connectable controllers | Maximum of 15 controllers (one master, 14 slaves) per SC-HG1-C unit | |||||
Supply voltage (Note 3) | 24 V DC ±10 %, including 0.5 V ripple (P-P) | |||||
Current consumption | 80 mA or less | |||||
Communication method | Switchable CC-Link Ver.1.10 or 2.00 | |||||
Remote station type | Remote device station | |||||
Number of occupied station | CC-Link Ver.1.10: 4 stations, CC-Link Ver.2.00: Switchable 2 or 4 stations | |||||
Station No. setting | 1 to 64 (0 and 65 or more: Error) | |||||
Communication speed | 10 Mbps | 5 Mbps | 2.5 Mbps | 625 kbps | 156 kbps | |
Maximum transmission distance |
100 m 328.084 ft |
160 m 524.934 ft |
400 m 1,312.336 ft |
900 m 2,952.756 ft |
1,200 m 3,937.008 ft |
|
Pollution degree | 2 | |||||
Operating altitude | 2,000 m 6561.68 ft or less (Note 4) | |||||
Environmental resistance |
Protection | IP40 (IEC) | ||||
Ambient temperature | -10 to +45 ℃ +14 to +113 ℉ (No dew condensation or icing allowed), Storage: -20 to +60 ℃ -4 to +140 ℉ | |||||
Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH | |||||
Voltage withstandability | 1,000 V AC for one min. between all supply terminals connected together and enclosure | |||||
Insulation resistance | 20 MΩ or more, with 250 V DC megger between all supply terminals connected together and enclosure | |||||
Vibration resistance | 10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude (10 to 58 Hz), maximum acceleration 49 m/s2(58 to 150 Hz) in X, Y and Z directions for two hours each | |||||
Shock resistance | 98 m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each | |||||
Material | Enclosure: Polycarbonate | |||||
Communication cable | Specified cable (shielded twisted cable) (Note 5) | |||||
Weight | Net weight: 80 g approx., Gross weight: 130 g approx. |
Notes:
1) | Where measurement conditions have not been specified precisely, the conditions used were ambient temperature +20℃+68℉. |
---|---|
2) | If our product will be incorporated in a customer product that will comply with the EMC Directive / EMC Regulations , install our product in a conductive box in accordance with "PLC User's Manual [Published by Mitsubishi Electric Corporation]". |
3) | Power is supplied from a connected controller / master controller. |
4) | Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m. |
5) | Use only a special-use communication cable that is approved by the CC-Link Partner Association. |
Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)