HL (AZH) Micro Limit Switch (Discontinued Products)

Rating/ Performance

Ratings

Load Standard type Bifurcated type
Resistive Lamp Inductive Motor Resistive
N.C. N.O.
125 V AC 5A 1.5A 3A 2A 1A 0.1A
250 V AC 5A 1.5A 3A 1A 0.5A -
8 V DC 5A - 1.5A - - 0.1A
14 V DC 5A - 1.5A - - 0.1A
24 V DC - - - - - -
30 V DC 5A - 1.5A - - 0.1A
125 V DC 0.5A - 0.05A - - -
250 V DC 0.25A - 0.03A - - -

Notes)

1. The values above indicate steady-state current.
2. Parameter of inductive load: AC power factor: Min. 0.4; DC time constant: Max. 7 ms.
3. Lamp load generates 10 times of inrush current.
4. Motor load generates 6 times of inrush current.

Characteristics

タイプ Standard type Bifurcated type
Screw terminal type Connector type
Contact arrangement 1 Form C 1 Form C (Bifurcated contact)
Contact resistance Initial: Max. 15 mΩ Initial: Max. 100 mΩ Initial: Max. 150 mΩ
Contact material AgCdO Au clad Ag alloy (Cadmium free)
Insulation resistance Initial: Min. 100MΩ (at 500 V DC)
Initial breakdown voltage 1,000 Vrms for 1 min. between non-consecutive terminals
1,500 Vrms for 1 min. between dead metal parts and terminals
1,500 Vrms for 1 min. between ground and terminals
Shock
resistance
Free position Max. 98 m/s2 {10 G}
Full operating position Max. 294 m/s2 {30 G}
Vibration resistance 10 to 55 Hz (Double amplitude for max. 1.5 mm)
Mechanical life 107 (at 120 cpm)
Electrical life 5×105 (at 20 cpm, 5 A 250 V AC resistive load) 5×105 (at 20 cpm, 0.1 A 125 V AC resistive load)
Ambient temperature -10 to +80 ℃ +14 to +176 ℉
Ambient humidity Max. 95% R.H.
Max. switching frequency Max. 120 cpm

Protective characteristics

Protective construction Die cast case Plastic case
IEC
IP64
IP67 -

Operating characteristics

Die casting case

Characteristics Operating
force, max.
N
(gf)
Release force,
min. N
(gf)
Pretravel, max.
mm
(inch)
Movement differential,
max.
mm
(inch)
Overtravel, min.
mm
(inch)
Operating
position,
max. mm
(inch)
Panel mount push plunger 11.8
(1200)
4.90
(500)
1.5
(0.059)
0.1
(0.004)
3.0
(0.118)
17.4±0.8
(0.685±0.031)
Panel mount roller plunger 11.8
(1200)
4.90
(500)
1.5
(0.059)
0.1
(0.004)
3.0
(0.118)
23.4±0.8
(0.921±0.031)
Panel mount cross roller plunger 11.8
(1200)
4.90
(500)
1.5
(0.059)
0.1
(0.004)
3.0
(0.118)
23.4±0.8
(0.921±0.031)
Sealed push plunger 11.8
(1200)
4.90
(500)
1.5
(0.059)
0.1
(0.004)
3.0
(0.118)
30.0±0.8
(1.181±0.031)
Sealed roller plunger 11.8
(1200)
4.90
(500)
1.5
(0.059)
0.1
(0.004)
3.0
(0.118)
41.3±0.8
(1.626±0.031)
Sealed cross roller plunger 11.8
(1200)
4.90
(500)
1.5
(0.059)
0.1
(0.004)
3.0
(0.118)
41.3±0.8
(1.626±0.031)
Short roller lever 3.92
(400)
0.78
(80)
2.0
(0.079)
0.3
(0.012)
4.0
(0.157)
23.1±0.8
(0.909±0.031)
Roller lever 2.45
(250)
0.39
(40)
4.0
(0.157)
0.6
(0.024)
7.0
(0.276)
23.1±0.8
(0.909±0.031)
One-way short roller lever 3.92
(400)
0.78
(80)
2.0
(0.079)
0.3
(0.012)
4.0
(0.157)
34.3±0.8
(1.350±0.031)
One-way short lever 2.45
(250)
0.39
(40)
4.0
(0.157)
0.6
(0.024)
7.0
(0.276)
34.3±0.8
(1.350±0.031)

Plastic case

Characteristics Operating
force, max.
N
(gf)
Release force,
min. N
(gf)
Pretravel, max.
mm
(inch)
Movement differential,
max.
mm
(inch)
Overtravel, min.
mm
(inch)
Operating
position,
max. mm
(inch)
Push plunger 5.88
(600)
0.98
(100)
1.5
(0.059)
0.1
(0.004)
3.0
(0.118)
25.4±0.8
(1.000±0.031)
Roller plunger 5.88
(600)
0.98
(100)
1.5
(0.059)
0.1
(0.004)
3.0
(0.118)
31.4±0.8
(1.236±0.031)
Roller plunger 5.88
(600)
0.98
(100)
1.5
(0.059)
0.1
(0.004)
3.0
(0.118)
31.4±0.8
(1.236±0.031)
Panel mount push plunger 5.88
(600)
0.98
(100)
1.5
(0.059)
0.1
(0.004)
3.0
(0.118)
17.4±0.8
(0.685±0.031)
Panel mount roller plunger 5.88
(600)
0.98
(100)
1.5
(0.059)
0.1
(0.004)
3.0
(0.118)
23.4±0.8
(0.921±0.031)
Panel mount cross roller plunger 5.88
(600)
0.98
(100)
1.5
(0.059)
0.1
(0.004)
3.0
(0.118)
23.4±0.8
(0.921±0.031)
Sealed push plunger 5.88
(600)
0.98
(100)
1.5
(0.059)
0.1
(0.004)
3.0
(0.118)
30.0±0.8
(1.181±0.031)
Sealed push plunger 5.88
(600)
0.98
(100)
1.5
(0.059)
0.1
(0.004)
3.0
(0.118)
41.3±0.8
(1.626±0.031)
Sealed cross roller plunger 5.88
(600)
0.98
(100)
1.5
(0.059)
0.1
(0.004)
3.0
(0.118)
41.3±0.8
(1.626±0.031)
Short roller lever 3.92
(400)
0.78
(80)
2.0
(0.079)
0.3
(0.012)
4.0
(0.157)
23.1±0.8
(0.909±0.031)
Roller lever 2.45
(250)
0.39
(40)
4.0
(0.157)
0.6
(0.024)
7.0
(0.276)
23.1±0.8
(0.909±0.031)
One-way short roller lever 3.92
(400)
0.78
(80)
2.0
(0.079)
0.3
(0.012)
4.0
(0.157)
34.3±0.8
(1.350±0.031)
One-way short lever 2.45
(250)
0.39
(40)
4.0
(0.157)
0.6
(0.024)
7.0
(0.276)
34.3±0.8
(1.350±0.031)
Flexible 0.88
(90)
- 30.0
(1.181)
- 20.0
(0.787)
-

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region







BY PHONE

Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)