【Notification of Manufacturer Change for Panasonic Industrial Devices SUNX Products and Panasonic Industrial Devices SUNX Tatsuno Products】
From April 1, 2024, the terms "Panasonic Industrial Devices SUNX Co., Ltd." and "Panasonic Industrial Devices SUNX Tatsuno Co., Ltd."
in this page and in the manuals and other documents to be downloaded will all be replaced with "Panasonic Industry Co., Ltd." and applied accordingly.
Business > Industrial Devices > Automation Controls Top > FA Sensors & Components > Timers / Counters / FA Componets > Counters > LC4H Electronic Counters(DIN 48)(Discontinued Products) > Rating/ Performance
We are sorry, the products have been discontinued. Please refer to the details of the discontinued products and the recommended substitutes list below.
|
|
Type | Ralay output type | Transistor output type | ||||
---|---|---|---|---|---|---|
Item | AC type | DC type | AC type, AC/DC type | DC type | ||
Rating | Rated operating voltage | 100 to 240 V AC, 24 V AC | 12 to 24 V DC | 100 to 240 V AC, 24 V AC, 24 V AC/DC | 12 to 24 V DC | |
Rated frequency | 50/60 Hz common | - | 50/60 Hz common | - | ||
Rated power consumption | Max. 10 V A | Max. 3 W | Max. 10 V A | Max. 3 W | ||
Rated control capacity | 5 A 250 V AC (resistive load) | 100 mA 30 V DC | ||||
Input mode | Addition (UP)/Subtraction (DOWN)/Direction (DIR)/Individuality (IND)/Phase (PHASE) 5 modes selectable by DIP switch |
|||||
Max. counting speed | 30 Hz/5 kHz (selectable by DIP switch) | |||||
Counting input (Input 1, 2) | Min. input signal width: 16.7 ms at 30 Hz/0.1 ms at 5 kHz, ON time: OFF time = 1:1 | |||||
Reset input | Min. input signal width: 1 ms, 20 ms (selected by DIP switch) | |||||
Lock input | Min. input signal width: 20 ms | |||||
Input signal |
Contact or Open collector input/Input impedance: 1 kΩ or less, Input residual voltage: 2 V or less, Open impedance: 100 kΩ or more, Max. energized voltage: 40 V DC |
|||||
Output mode | HOLD-A/HOLD-B/HOLD-C/SHOT-A/SHOT-B/SHOT-C/SHOT-D (7 modes selectable by DIP switch) | |||||
One shot output time | Approx. 1 s | |||||
Indication | 7-segment LCD, Counter value (backlight red LED), Setting value (backlight yellow LED) | |||||
Digit | 4-digit display type –999 to 9999 (–3 digits to +4 digits) (0 to 9999 for setting) 6-digit display type –99999 to 999999 (–5 digits to 6 digits) (0 to 999999 for setting) |
|||||
Memory | EEP-ROM (Overwriting times: 105 ope. or more) | |||||
Contact | Contact arrangement | Relay (1c/1a*) *8-pin type only |
1 Form A (Open collector) | |||
Initial contact resistance | 100 mΩ (at 1 A 6 V DC) | - | ||||
Contact material | Ag alloy/Au flush | - | ||||
Life | Mechanical (contact) | 2×107 ope. (Except for switch operation parts) | - | |||
Electrical (contact) | 105 ope. (At rated control voltage) | 107 ope. (At rated control voltage) | ||||
Electrical | Allowable operating voltage range | 85 to 110 % of rated operating voltage | ||||
Break down voltage (Initial value) |
Between live and dead metal parts: 2,000 Vrms for 1 min (11-pin type) Between input and output: 2,000 Vrms for 1 min Between open contacts: 1,000 Vrms for 1 min |
Between live and dead metal parts: 2,000 Vrms for 1 min (11-pin type) Between input and output: 2,000 V AC for 1 min |
||||
Insulation resistance (At 500 V DC) (Initial value) | Between live and dead metal parts: Min. 100 MΩ (11-pin type) Between input and output: Min. 100 MΩ Between open contact: Min. 100 MΩ |
Between live and dead metal parts: Min. 100 MΩ (11-pin type) Between input and output: Min. 100 MΩ |
||||
Temperature rise | Max. 65°C (under the flow of nominal operating current at nominal voltage) | - | ||||
Mechanical | Vibration resistance |
Functional | 10 to 55 Hz (1 cycle/min), single amplitude: 0.35 mm (10 min on 3 axes) | |||
Destructive | 10 to 55 Hz (1 cycle/min), single amplitude: 0.75 mm (1 h on 3 axes) | |||||
Shock resistance |
Functional | Min. 98 m 321.522 ft./s2 (4 times on 3 axes) | ||||
Destructive | Min. 294 m 964.567 ft./s2 (5 times on 3 axes) | |||||
Operating conditions |
Ambient temperature | –10°C to 55°C/ +14°F to +131°F | ||||
Ambient humidity | Max. 85 % RH (non-condensing) | |||||
Air pressure | 860 to 1,060 h Pa | |||||
Ripple rate | - | 20 % or less | - | 20 % or less | ||
Connection | 8-pin/11-pin/screw terminal | |||||
Protective construction | IP66 (front panel with a rubber gasket) |
Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)