December 28, 2022 |
|
|
Application Standard
Safety standard |
EN61812-1 |
Pollution Degree 2/Overvoltage Category II |
EMC |
(EMI)EN61000-6-4 |
|
Radiation interference electric field strength |
EN55011 Group 1 ClassA |
Noise terminal voltage |
EN55011 Group 1 ClassA |
(EMS)EN61000-6-2 |
|
Static discharge immunity |
EN61000-4-2 |
4 kV contact |
8 kV air |
RF electromagnetic field immunity |
EN61000-4-3 |
10 V/m AM modulation (80 MHz to 1 GHz) |
10 V/m pulse modulation (895 MHz to 905 MHz) |
EFT/B immunity |
EN61000-4-4 |
2 kV (power supply line) |
1 kV (signal line) |
Surge immunity |
EN61000-4-5 |
1 kV (power line) |
Conductivity noise immunity |
EN61000-4-6 |
10 V/m AM modulation (0.15 MHz to 80 MHz) |
Power frequency magnetic field immunity |
EN61000-4-8 |
30 A/m (50 Hz) |
Voltage dip/Instantaneous stop/Voltage fluctuation immunity |
EN61000-4-11 |
10 ms, 30% (rated voltage) |
100 ms, 60% (rated voltage) |
1,000 ms, 60% (rated voltage) |
5,000 ms, 95% (rated voltage) |