Version-Up information (Ver.2.30 to Ver.2.40 Update: November 1, 2019)
The following points have been upgraded.
[Specification update]
- "Mewtocol connection timeout" can be set in the range of 5 to 60 seconds. Old version is fixed 60 seconds.)
[Change specifications]
- Changed "Sending cycle of collecting command" to "Waiting time of collecting command" in RS232C/485 setup dialog and added radio button to select "Time from send command" or "Time from receive command".
[Modify the below errors]
- Cannot get the logging files through USB in some case.
Version-Up information (Ver.2.20 to Ver.2.30 Update: September 1, 2016)
The following points have been upgraded.
[Specification update]
- Add ability to synchronize with the clock of KW1M-H.
- Add the ability in the special DT register to count up every one second.
- Add a new trigger that occurs when a register value is different from the previous one.
[Change specifications]
- The same file name can not be registered.
- When the subject of the data set is "main unit", device "Y" can not be selected.
Version-Up information (Ver.2.13 to Ver.2.20 Update: November 10, 2015)
The following points have been upgraded.
[Specificaton update]
- Add 'Main unit' as an option for logging device.
- Add ‘1,2,3,4’ as options for FTP retry interval.
[Change specifications]
- When the usage is set to 'Computer link' at RS232C/R485 setup, it can't register communication I/F at COM1 and COM2.
- Add message when you click OK without check at 'Create folder'.
- Change the inital value
--'Check battery voltage' : from No to Yes
- Add setup to collect 64-bit data.
- Available to set that it doesn't save the setup data history in system file.
- Available to shift language without executing by administrator.
- Available to download csv file via USB cable.
[Modify the below errors]
- Scan time is not displayed correctly.
- Contact status, ON and OFF, is not correct when you see the print preview and you print it.
- It finishes when you input value with 16 digit or more as a setting value at data setting.
Version-Up information (Ver.2.12 to Ver.2.13 Update: June 6, 2014)
The following points have been upgraded.
[Specification update]
- Half-width characters "<", ">" and " : " are available in an e-mail address.
Version-Up information (Ver.2.11 to Ver.2.12 Update: January 17, 2014)
The following points have been upgraded.
[Change specifications]
- Support Microsoft (R) Windows 8.
- File list function is improved.
- Shift to upper folder by click button.
- Delete and download folders.
- Printing function is improved.
- Print conversion factor and unit.
Version-Up information (Ver.2.10 to Ver.2.11 Update: August 6, 2012)
The following points have been upgraded.
[Modify the below errors]
- When connecting by 1:1, no values are displayed for the Current value monitor.
- The information of “Sending cycle of collecting command・Retry of collecting command” is not printed.
- When MODBUS communication, the display is different from the selected device type with Logging device registration.
Version-Up Information(Ver.2.01 to Ver.2.10)
The following points have been upgraded.
[Add functions]
- Retry function for FTP client.
- Prohibited letter for logging file name, system history file name, trigger file name.
- Prohibited letter for logging device name.
[Change specifications]
- The initial values are changed.
Logging command retry : not available -> available
Use most recent data for the accumulation data : not available->Available
[Modify the below errors]
- At MODBUS, ‘A to F’ can’t be input for logging device address input.
Version-Up Information(Ver.2.00 to Ver.2.01)
The following points have been upgraded.
[Modify the below errors]
- A help function revised malfunction not to start.
- By data setting, the permutation choice of data revised malfunction to have in spite of MEWTOCOL choice.
- With print, the print indication of an SMTP server, the FTP server revised funny malfunction.
Version-Up Information(Ver.1.21 to Ver.2.00)
The following points have been upgraded.
[Add functions]
- MODBUS (RTU) protocol is added.
- Display of current value monitor is improved.
- Communication error → "−" is displayed.
- Display according to the condition set with logging device.
- It is possible to reply with real-value for command from the upper.
[Change functions]
- In case of using Easy-setup, "Make the destination folder name of logging file[CF]." is checked.
Version-Up Information(Ver.1.20 to Ver.1.21)
The following points have been upgraded.
[Add functions]
- Method of data logging can be set.
[Change functions]
- The initial value of the below items are changed.
- Communication I/F COM1(RS232C) to COM2(RS485)
- Transmission interval of collecting command 10ms to 100ms
[Modify the below errors]
- When file is overwritten after timed out at logging file list, downloaded file is deleted.